Sonoclot® NonActivated Kit
Basic Information
- Brand Name
- Sonoclot® NonActivated Kit
- Primary DI
- B55880004251
- Version / Model
- 800-0425
- Catalog Number
- 800-0425
- Company Name
- SIENCO, INC.
- Labeler DUNS
- 064039514
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 100
- Record Status
- Published
- Publish Date
- 2021-07-19
- Public Version
- 1
- Public Version Date
- 2021-07-27
- Public Version Status
- New
- Public Device Record Key
- 7feb0ebc-3f94-4de7-9261-41e93671ce08
Device Description
The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diagnostic test for use with the Sonoclot® Coagulation & Platelet Function Analyzer System. It may be used with native whole blood, citrated whole blood, and plasma. The Non-Activated Kit may either be used as a non-activated clotting test or as a general use test with user provided activators. It is intended for customer designed hemostasis monitoring on the Sonoclot Analyzer. The Non-Activated cuvette allows for coagulation monitoring using tissue activation, thrombin activation, and other custom activators. Some of the applications for the Non-Activated test with the addition of customer determined reagents are monitoring of fibrin formation, fibrinolysis, hyperfibrinolysis and clot retraction. When used with the Sonoclot Analyzer System, the Non-Activated test provides quantitative Onset/ACT and Clot Rate results as well as qualitative and quantitative information on the Sonoclot Signature including: fibrin formation, platelet function, and hyperfibrinolysis. Each kit contains 100 lidded plastic cuvettes, 100 probes, and instructions for use. The cuvettes contain a magnetic stir bar.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JPA | System, Multipurpose For In Vitro Coagulation Studies | Hematology | 864.5425 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 55996 | Multiple coagulation factor IVD, kit, clotting | A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative determination of one or multiple coagulation factors, coagulation intermediates and/or their activated components in a clinical specimen, using a clotting method. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | B55880004250 | HIBCC | ||||
| Primary | B55880004251 | HIBCC |
Customer Contacts
- Phone
- 303-420-1148
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K952560 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- – 25 Degrees Celsius