Basic Information

Brand Name
LiverMultiScan
Primary DI
B554LMS3100
Version / Model
3.1.0
Company Name
PERSPECTUM LTD
Labeler DUNS
218593632
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2019-09-17
Public Version
4
Public Version Date
2023-12-04
Public Version Status
Update
Public Device Record Key
5fa2b394-f082-4540-a45f-39bb3c9231a6

Device Description

LiverMultiScan (LMSv3) is a standalone software device. The purpose of the LiverMultiScan (LMSv3) device is to assist the trained operator with the evaluation of information from Magnetic Resonance (MR) images from a single time-point (patient visit). The LiverMultiScan (LMSv3) is a post-processing software device, a trained operator uses tools such as automatic liver segmentation and region of interest placement upon previously acquired MR images, from which a summary report is generated. The summary report is then sent to an interpreting clinician. The interpreting clinician needs to take into consideration the device’s limitations and accuracy during clinical interpretation. LiverMultiScan (LMSv3) is not intended to replace the established procedures for the assessment of a patients liver health by an interpreting clinician, providing many opportunities for competent human intervention in the interpretation of images and information displayed. The device is intended to be used by a trained operator to generate metrics for subsequent interpretation by a clinician. The metrics are intended to be used as an additional diagnostic input to provide information to clinicians as part of a wider diagnostic process. It is expected that in the normal course of liver disease diagnosis, patients will present with clinical symptoms or risk factors which may indicate liver disease. Liver function tests, blood tests, ultrasound scanning as well as liver biopsy are all expected to be used at the discretion of a qualified clinician in addition to information obtained from the use of LiverMultiScan (LMSv3) metrics. The purpose of a LiverMultiScan (LMSv3) metrics is to provide imaging information to assist in characterizing tissue in the liver, which are additional to existing methods for obtaining information relating to the liver. LiverMultiScan (LMSv3) metrics are not intended to replace any existing diagnostic source of information, but can be used to identify patients who

Device Characteristics

Single Use
No
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
No
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
Yes

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
LNH System, Nuclear Magnetic Resonance Imaging

GMDN Terms

Code Name
57812 Radiology DICOM image processing application software

Identifiers

Type ID
Primary B554LMS3100

Customer Contacts