FDA UDI In Commercial Distribution 🇺🇸 United States

Hepatica

DI: B554HEPATICA100 · Model: 1.0.0 · PERSPECTUM LTD
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Let the assistant research this device

The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.

Free to try · every answer cites its records

Basic Information

Brand Name
Hepatica
Primary DI
B554HEPATICA100
Version / Model
1.0.0
Company Name
PERSPECTUM LTD
Labeler DUNS
218593632
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2021-02-12
Public Version
4
Public Version Date
2023-12-04
Public Version Status
Update
Public Device Record Key
e7965190-e637-41a9-9f8d-ca9ebd830430

Device Description

Hepatica (Hepatica v1) is a post-processing medical device software that presents quantified metrics which may contribute to the assessment of a patient’s liver health.Hepatica (Hepatica v1) uses image visualisation and analysis tools to process DICOM 3.0 compliant magnetic resonance image datasets to produce semi-automatic segmented 3D models of the liver based on the work of Couinaud and the Brisbane 2000 terminology. For each identified Couinaud segment, volumetric data is determined and reported. Hepatica (Hepatica v1) may also report iron corrected-T1 (cT1) and PDFF calculated using the IDEAL methodfrom multi-slice acquisitions, on a per segment basis, over the whole liver. Both metrics present numerical values of different fundamental liver tissue characteristics that can be used as measures of liver tissue health.Hepatica (Hepatica v1) provides trained clinicians with additional information to evaluate the volume and health of a patient’s liver on a segmental basis. It is not intended to replace the established procedures for the assessment of a patient’s liver health. However, information gathered through existing diagnostic tests, clinical evaluation of the patient, as well Hepatica(Hepatica v1), may support surgical decision making.

Device Characteristics

Single Use
No
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
Yes
Has Lot/Batch Number
No
Has Manufacturing Date
No
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
LNH System, Nuclear Magnetic Resonance Imaging

GMDN Terms

Code Name
57812 Radiology DICOM image processing application software

Identifiers

Type ID
Primary B554HEPATICA100

Customer Contacts