Instrumentation Difra
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Instrumentation Difra
- Primary DI
- B51617550
- Version / Model
- AquaStar 115V 2.0
- Catalog Number
- 17550
- Company Name
- Instrumentation Difra SA
- Labeler DUNS
- 370173410
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-09-17
- Public Version
- 2
- Public Version Date
- 2020-11-19
- Public Version Status
- Update
- Public Device Record Key
- 040d8c91-089b-48ba-9be1-0f7e681bfb5a
Device Description
The water caloric stimulator is a device that delivers a stream of water to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements. An internal chronometer offers through a second rotary switch the possibility to select the stimulation time. Five stimulation times are available: 20, 30, 40,50 and 60s By default, temperature values are 27°C, 30°C, 37°C and 44°C. Minimal temperature reachable: 3°C over the ambient temperature Maximal temperature reachable: 48°C Water flow: fixed, 350ml/min Timer Requires a water supply and an outlet Intended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to the caloric testing process.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- Yes
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| ETP | Stimulator, Caloric-Water | Ear, Nose, Throat | 874.1800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 34891 | Diagnostic caloric vestibular stimulation system | An assembly of devices intended to evaluate a patient’s vestibular function through the application of heat and/or cold stimuli in the form of a stream of air or water into the ear canal, whereby involuntary horizontal eye movements (nystagmus) are produced and measured using a nystagmograph. The procedure may also be referred to as caloric reflex test, and is typically used for assessing a patient's balance system and/or to test for brainstem death. It typically consists of an irrigation system that includes a pump, valves, heaters and regulators to control the rate of flow and temperature of the medium. This device is typically used in an ear/nose/throat (ENT) department. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B51617550 | HIBCC |
Customer Contacts
- Phone
- 260.436.1436
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Height | 11.5 | Centimeter | |
| Depth | 35.5 | Centimeter | |
| Length | 31 | Centimeter | |
| Weight | 5 | Kilogram |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 5 – 55 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 30 – 90 Degrees Celsius
- Type
- Handling Environment Temperature
- Temperature Range
- 5 – 35 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 90 Percent (%) Relative Humidity