FDA UDI
In Commercial Distribution
🇺🇸 United States
ADVANCED PATIENT MONITOR
DI: B510PM2000TM1
·
Model: PM-2000TM
·
ADVANCED INSTRUMENTATIONS, INC.
Product Codes
14
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- ADVANCED PATIENT MONITOR
- Primary DI
- B510PM2000TM1
- Version / Model
- PM-2000TM
- Company Name
- ADVANCED INSTRUMENTATIONS, INC.
- Labeler DUNS
- 608736880
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-04-16
- Public Version
- 1
- Public Version Date
- 2020-04-24
- Public Version Status
- New
- Public Device Record Key
- 37a65139-3f56-49f8-b1a7-350662845ab7
- Distribution End Date
- 2028-04-15
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBQ | Analyzer, Gas, Enflurane, Gaseous-Phase (Anesthetic Concentration) | Anesthesiology | 868.1500 | 2 |
| FLL | Thermometer, Electronic, Clinical | General Hospital | 880.2910 | 2 |
| DRT | Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm) | Cardiovascular | 870.2300 | 2 |
| CCL | Analyzer, Gas, Oxygen, Gaseous-Phase | Anesthesiology | 868.1720 | 2 |
| DSI | Detector And Alarm, Arrhythmia | Cardiovascular | 870.1025 | 2 |
| MHX | Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Cardiovascular | 870.1025 | 2 |
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
| DQA | Oximeter | Cardiovascular | 870.2700 | 2 |
| CBR | Analyzer, Gas, Nitrous-Oxide, Gaseous Phase (Anesthetic Conc.) | Anesthesiology | 868.1700 | 2 |
| MLD | Monitor, St Segment With Alarm | Cardiovascular | 870.1025 | 2 |
| CBS | Analyzer, Gas, Halothane, Gaseous-Phase (Anesthetic Conc.) | Anesthesiology | 868.1620 | 2 |
| CCK | Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase | Anesthesiology | 868.1400 | 2 |
| DSK | Computer, Blood-Pressure | Cardiovascular | 870.1110 | 2 |
| DSA | Cable, Transducer And Electrode, Patient, (Including Connector) | Cardiovascular | 870.2900 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36553 | Patient monitoring system module, multifunction | A small unit dedicated to the measurement and displays of several physiological parameters, e.g., electrical activity of the heart, respiratory rate, temperature, blood pressure, pulse, and oximetry. The signals are obtained through connected cables/leads/probes. It is designed to operate as part of a patient monitoring system enhancing the function of this system (the parent device). The module automatically plugs into the parent device when the user places it into a standardized slot in the parent device which then operates as a mainframe computer displaying the various parameters/information measured and provided by this module. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B510PM2000TM1 | HIBCC |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K132077 | 000 |