FDA UDI
In Commercial Distribution
🇺🇸 United States
Surgical Direct
DI: B382SD123690
·
Model: SD12369
·
Surgical Direct, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Surgical Direct
- Primary DI
- B382SD123690
- Version / Model
- SD12369
- Catalog Number
- SD12369
- Company Name
- Surgical Direct, Inc.
- Labeler DUNS
- 124367223
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-04-29
- Public Version
- 1
- Public Version Date
- 2020-05-07
- Public Version Status
- New
- Public Device Record Key
- 6f9340e9-e72f-4790-822d-6990ebd1921a
Device Description
Suction and Irrigation Handle for 5 and 10mm Sheaths, Double Trumpet Valve
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCX | Apparatus, Suction, Operating-Room, Wall Vacuum Powered | General Hospital | 880.6740 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 41978 | Surgical irrigation/aspiration system | An assembly of devices used to intermittently or continuously irrigate and/or aspirate body cavities and wounds during a general surgical procedure. It provides for the removal of loose tissue, fluids, and other debris to keep the surgical site clear, helping to optimize visualization and access. The assembly typically includes a mains electricity (AC-powered) pump, collection bottles, tubing, and connectors. It may be used together with an irrigation catheter. It is not intended to be used for the administration of parenteral fluids, infusion of drugs, or for any life sustaining purposes. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B382SD123690 | HIBCC |
Customer Contacts
- Phone
- +1 (800) 519-3293
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 5 | Millimeter |