FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Veress Needle 150mm w/Straight Hub
DI: B354OSVN150S0
·
Model: OSVN150S
·
ORANGE SURGICAL INSTRUMENTS, LLC
Product Codes
3
GMDN Terms
5
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Veress Needle 150mm w/Straight Hub
- Primary DI
- B354OSVN150S0
- Version / Model
- OSVN150S
- Company Name
- ORANGE SURGICAL INSTRUMENTS, LLC
- Labeler DUNS
- 047063695
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-11-15
- Public Version
- 7
- Public Version Date
- 2024-01-01
- Public Version Status
- Update
- Public Device Record Key
- a6e6ec48-6a6d-4de1-a763-b0654957c5d7
- Distribution End Date
- 2023-07-01
Device Description
Veress Needle 150mm w/Straight Hub
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, General & Plastic Surgery | Gastroenterology, Urology | 876.1500 | 2 |
| HIF | Insufflator, Laparoscopic | Obstetrics/Gynecology | 884.1730 | 2 |
| GEI | Electrosurgical, Cutting & Coagulation & Accessories | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60390 | Laparoscopic wound closure thread | A sterile, bioabsorbable, implantable, device intended to be used exclusively during laparoscopic surgery to approximate subcutaneous tissue after removal of the laparoscopic sleeve/port. It consists of a suture with an attached short tag (anchor), and often includes a plastic guide which can take different forms depending on the method of laparoscopic entry, and a metal (e.g., stainless steel) and/or plastic pusher. The guide and pusher are used to deliver the suture so that the tag is deep to the wound, with the suture trailing so that it can be ligated on removal of the laparoscopic sleeve/port. | Yes | Active |
| 38559 | Insufflation gas conditioning tubing set | A collection of sterile and non-sterile devices intended to be used with an insufflation gas conditioning system and/or a laparoscopic gas distention system, or other gas source, to condition the insufflation gas stream [typically carbon dioxide (CO2)] by heating and humidifying it before introduction into the peritoneal cavity or a wound during laparoscopic or open surgery. It is available in various configurations but typically includes a connection tube for connection to the gas source, an electrically-heated tube for transport of the conditioned gas to the operative site, a humidification chamber, a gas filter, and connectors. This is a single-use device. | No | Active |
| 33596 | Endoscopic electrosurgical handpiece/electrode, monopolar, reusable | An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and requires a patient contact return electrode to complete the circuit. This is a reusable device. | No | Active |
| 61875 | Endoscopic electrosurgical electrode, monopolar, single-use | A sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It is available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece or housing and has no electrical or mechanical controls (e.g., does not include ring-handles); it is not intended for gas-enhanced electrosurgery. This is a single-use device. | No | Active |
| 45130 | Tissue extraction bag | An impervious, flexible, sterile container intended to be used during minimally-invasive, typically keyhole, surgical techniques (e.g., laparoscopic) to extract dissected patient body tissue. The device is inserted into the body through a large bore cannula port, and the tissue to be extracted is placed in the bag with trans-cannula instruments and evacuated through the cannula. The device typically includes an x-ray detectable thread. This device may be used for surgical interventions such as an appendectomy, colonectomy, lymphadenectomy, or gallbladder removal. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | B354OSVN150S10 | HIBCC | 10 | Not in Commercial Distribution | 2019-11-15 | |
| Primary | B354OSVN150S0 | HIBCC |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K101733 | 000 |