FDA UDI
In Commercial Distribution
🇺🇸 United States
DrugCheck
DI: B2983044510
·
Model: 30445
·
Express Diagnostic Int'l, Inc.
Product Codes
4
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- DrugCheck
- Primary DI
- B2983044510
- Version / Model
- 30445
- Catalog Number
- 30445
- Company Name
- Express Diagnostic Int'l, Inc.
- Labeler DUNS
- 015875273
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-04-23
- Public Version
- 3
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- 99c43735-49d3-4725-9378-595b3ef08204
Device Description
4 Panel Dip Drug Test, AMP-COC-MET-THC
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LDJ | Enzyme Immunoassay, Cannabinoids | Clinical Toxicology | 862.3870 | 2 |
| LAF | Gas Chromatography, Methamphetamine | Clinical Toxicology | 862.3610 | 2 |
| DIO | Enzyme Immunoassay, Cocaine And Cocaine Metabolites | Clinical Toxicology | 862.3250 | 2 |
| DKZ | Enzyme Immunoassay, Amphetamine | Clinical Toxicology | 862.3100 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46994 | Multiple drugs of abuse IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of multiple drugs of abuse in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B2983044510 | HIBCC |
Customer Contacts
- Phone
- 507-526-3951
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 4 – 30 Degrees Celsius