FDA UDI
In Commercial Distribution
🇺🇸 United States
BRAEBON SpO2 Cable for MediByte
DI: B14088960
·
Model: 8896
·
Braebon Medical Corporation
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- BRAEBON SpO2 Cable for MediByte
- Primary DI
- B14088960
- Version / Model
- 8896
- Catalog Number
- 8896
- Company Name
- Braebon Medical Corporation
- Labeler DUNS
- 251731105
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-22
- Public Version
- 4
- Public Version Date
- 2021-11-10
- Public Version Status
- Update
- Public Device Record Key
- ff8d5040-f710-4865-b465-83c5ca4f48eb
Device Description
Finger probe for measuring blood oxygen saturation. Plugs directly into the MediByte.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MNR | Ventilatory Effort Recorder | Anesthesiology | 868.2375 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 37808 | Pulse oximeter probe, reusable | A photoelectric device designed to be applied externally to a body site (e.g., fingertip, ear lobe, bridge of nose, toe, or bridge of the foot) for the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in arterial blood using signals produced by a light-emitting diode (LED) and received by a photodetector. The signals are subsequently transmitted to an oximeter/monitor (not included) which measures and displays the SpO2. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B14088960 | HIBCC |
Customer Contacts
- Phone
- 613.831.6690
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K061764 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 60 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity