FDA UDI
In Commercial Distribution
🇺🇸 United States
Aries-L Lateral Lumbar Interbody System
DI: B06214509050
·
Model: 1450-9050
·
Osseus Fusion Systems, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Aries-L Lateral Lumbar Interbody System
- Primary DI
- B06214509050
- Version / Model
- 1450-9050
- Catalog Number
- 1450-9050
- Company Name
- Osseus Fusion Systems, LLC
- Labeler DUNS
- 933442068
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-05-12
- Public Version
- 1
- Public Version Date
- 2020-05-20
- Public Version Status
- New
- Public Device Record Key
- 11e8147d-e77f-47a4-8f7c-9cd755525fa9
Device Description
Slap Hammer Assembly
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GFB | Head, Surgical, Hammer | General, Plastic Surgery | 878.4820 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47814 | Orthopaedic implantation hammering attachment | A surgical instrument designed to be attached to another surgical implantation instrument or directly to an orthopaedic implant to provide a surface on which an operating surgeon can make strikes, with a surgical hammer or mallet, to insert an orthopaedic implant (e.g., an intramedullary nail). It is typically made of high-grade stainless steel and typically in the form of a cylindrical shaft with a threaded portion at the distal end (i.e., threaded into the implant or connected to the implantation instrument) and a broader, robust striking head (surface) at the proximal end. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B06214509050 | HIBCC |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K181347 | 000 |