FDA UDI
In Commercial Distribution
🇺🇸 United States
CROC Series Endoscopic Device
DI: 40666416140112
·
Model: H928N
·
Primed Instruments Inc
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
160
Basic Information
- Brand Name
- CROC Series Endoscopic Device
- Primary DI
- 40666416140112
- Version / Model
- H928N
- Catalog Number
- H928N
- Company Name
- Primed Instruments Inc
- Labeler DUNS
- 254491293
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 160
- Record Status
- Published
- Publish Date
- 2017-10-23
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 923efaa4-7576-497a-89d6-0190a3c4a51c
Device Description
High capacity single-use biopsy forceps with serrated jaws, ezSlide® sheath and no needle. HIBC/UPN: M453H928N3
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FCL | Forceps, Biopsy, Non-Electric | Gastroenterology, Urology | 876.1075 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38711 | Flexible endoscopic biopsy forceps, single-use | A flexible, manual, non-electrosurgical instrument intended to obtain tissue specimens during endoscopic procedures (e.g., gastro-urological endoscopy, laparoscopy, bronchoscopy, laryngoscopy) for histopathological examination. It is typically a flexible metal coil with a pair of scissors-like cups with cutting edge rims, which are operated by a control handle at the proximal end of the instrument. It is introduced into the body through an artificial orifice of the body or the working channel of the endoscope. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 40666416140112 | GS1 | ||||
| Unit of Use | 00666416140114 | GS1 |
Customer Contacts
- Phone
- 1-877-565-0565
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Required Working Channel: 3.2mm | ||
| Device Size Text, specify | Jaw Diameter: 2.8mm | ||
| Device Size Text, specify | Working Length: 230cm |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Biopsy forceps should be stored in the sterile package at room temperature in a clean and dry area away from direct sunlight. Case contains 8 dispenser boxes. Each dispenser box contains 20 devices.