FDA UDI
In Commercial Distribution
🇺🇸 United States
UNIVERSAL PLUS
DI: 30653405010771
·
Model: 60-5274-244
·
Conmed Corporation
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
5
Basic Information
- Brand Name
- UNIVERSAL PLUS
- Primary DI
- 30653405010771
- Version / Model
- 60-5274-244
- Catalog Number
- 60-5274-244
- Company Name
- Conmed Corporation
- Labeler DUNS
- 071595540
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 5
- Public Version Date
- 2024-02-09
- Public Version Status
- Update
- Public Device Record Key
- 611fe99a-2b62-476a-b6a8-ab2c0ddf4fd5
Device Description
UNIVERSAL PLUS LAPAROSCOPIC ELECTRODE WITH ESCHAR-RESISTANT COATING - SUCTION/IRRIGATION, 5MM X 44CM J-HOOK
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61875 | Endoscopic electrosurgical electrode, monopolar, single-use | A sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It is available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece or housing and has no electrical or mechanical controls (e.g., does not include ring-handles); it is not intended for gas-enhanced electrosurgery. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 20653405010774 | GS1 | BOX | 5 | In Commercial Distribution | |
| Primary | 30653405010771 | GS1 | ||||
| Unit of Use | 00653405010770 | GS1 |
Customer Contacts
- Phone
- +1(866)426-6633
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K952204 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 44 | Centimeter | |
| Outer Diameter | 5 | Millimeter |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 90 Percent (%) Relative Humidity
- Type
- Handling Environment Humidity
- Temperature Range
- High: 85 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- -29 – 60 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- 50 – 90 Degrees Fahrenheit
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 75 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- 16 – 27 Degrees Celsius
- Type
- Handling Environment Temperature
- Temperature Range
- 60 – 80 Degrees Fahrenheit
- Type
- Handling Environment Temperature
- Temperature Range
- -20 – 140 Degrees Fahrenheit
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 32 Degrees Celsius