FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 20886982031645
·
Model: 02.111.304.10
·
Synthes GmbH
Product Codes
2
GMDN Terms
1
Identifiers
3
Pkg Device Count
10
Basic Information
- Brand Name
- NA
- Primary DI
- 20886982031645
- Version / Model
- 02.111.304.10
- Catalog Number
- 0211130410
- Company Name
- Synthes GmbH
- Labeler DUNS
- 486711679
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 10
- Record Status
- Published
- Publish Date
- 2019-02-21
- Public Version
- 4
- Public Version Date
- 2024-02-27
- Public Version Status
- Update
- Public Device Record Key
- b9f48a30-d542-40b2-b49c-6228bc02794e
Device Description
1.25MM KIRSCHNER WIRE WITH TROCAR TIP/80MM
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HRS | Plate, fixation, bone | Orthopedic | 888.3030 | 2 |
| HWC | Screw, fixation, bone | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32854 | Orthopaedic bone pin, non-bioabsorbable | A thin, implantable rod intended to be used for the stabilization of a bone fracture or bone grafts, or for an osteotomy or arthrodesis. It is typically drilled into bone and may be smooth or threaded, solid or cannulated, and/or semi-flexible. Also known as a K-Wire, it may in addition be intended to assist with the introduction of a surgical instrument and/or implant; it is not intended for implantation into the intramedullary canal (i.e., not a nail). It is made of a material that is not chemically degraded or absorbed by natural body processes (e.g., stainless steel). Some designs may have a break-off shank and/or be coated to improve long-term fixation. This is a single-use device. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Secondary | H67902111304100 | HIBCC | ||||
| Primary | 20886982031645 | GS1 | ||||
| Unit of Use | 80886982031647 | GS1 |
Customer Contacts
- Phone
- +1(800)255-2500
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K103243 | 000 |