FDA UDI
In Commercial Distribution
🇺🇸 United States
Auto Suture
DI: 20884521539645
·
Model: OMST10BTSNL
·
Covidien LP
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Auto Suture
- Primary DI
- 20884521539645
- Version / Model
- OMST10BTSNL
- Company Name
- Covidien LP
- Labeler DUNS
- 058614483
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 6
- Public Version Date
- 2023-09-28
- Public Version Status
- Update
- Public Device Record Key
- 8bb13993-4d23-43e7-a70a-dd278404a4f7
Device Description
Blunt Tip Trocar
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, general & plastic surgery | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44794 | Surgical balloon dissector | A device used to dissect connective tissue layers creating access to a surgical site for a variety of surgical procedures. The device typically consists of a cannula, a distention balloon, an obturator, an inflation bulb, and a regulating valve(s). An endoscope is introduced into the cannula to monitor the dissection and/or the insertion process. The balloon is inflated to fill volume exerting pressure on the tissue layers. It is then deflated and removed, and distention is maintained by infusion of carbon dioxide (CO2) via the cannula. This device can be used for hernia repair, varicocele dissection, sympathectomy, lymph node biopsy, or perforator vein ligation. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 10884521539648 | GS1 | CASE | 5 | In Commercial Distribution | |
| Primary | 20884521539645 | GS1 |
Customer Contacts
- Phone
- +1(508)261-8000
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K924011 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 10 | Millimeter | |
| Device Size Text, specify | Short; |