FDA UDI
In Commercial Distribution
🇺🇸 United States
Medtronic Reusable Instrument
DI: 20673978069146
·
Model: 875-087
·
MEDTRONIC SOFAMOR DANEK, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
10
Basic Information
- Brand Name
- Medtronic Reusable Instrument
- Primary DI
- 20673978069146
- Version / Model
- 875-087
- Company Name
- MEDTRONIC SOFAMOR DANEK, INC.
- Labeler DUNS
- 830350380
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 10
- Record Status
- Published
- Publish Date
- 2022-10-15
- Public Version
- 1
- Public Version Date
- 2022-10-24
- Public Version Status
- New
- Public Device Record Key
- 3956a511-5906-4b5a-9640-e35516590893
Device Description
DISTRACTOR 875-087 PINS STER 12MM
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LXH | Orthopedic manual surgical instrument | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 56637 | Orthopaedic surgical distractor, internal | A hand-held manual surgical instrument designed to invasively distract (force apart) two bone surfaces to enable a surgical procedure. It typically aids in fracture reduction by helping to temporarily stabilize bones prior to definitive surgical fixation. It typically consists of a central threaded spindle, a static endpiece and a sliding carriage that can be adjusted using spindle nuts to/from the endpiece to widen or shorten the gap; it facilitates the attachment of orthopaedic bone pins (Schanz screws) screwed into the bones to be distracted. It is typically used for multiple injuries when it is advantageous to perform procedures on a standard operating table. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | 00673978069142 | GS1 | ||||
| Primary | 20673978069146 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]