FDA UDI
In Commercial Distribution
🇺🇸 United States
KIT KE226 COLON
DI: 20607915133898
·
Model: GK253
·
APPLIED MEDICAL RESOURCES CORPORATION
Product Codes
8
GMDN Terms
8
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- KIT KE226 COLON
- Primary DI
- 20607915133898
- Version / Model
- GK253
- Company Name
- APPLIED MEDICAL RESOURCES CORPORATION
- Labeler DUNS
- 187129135
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-09
- Public Version
- 8
- Public Version Date
- 2022-06-17
- Public Version Status
- Update
- Public Device Record Key
- d1318564-8688-45b3-924a-2334cab57ea5
Device Description
Kit Contains: C6001, 5mmX33cm PROB/VALV DUAL BAG 12/BX C4130, 5mmx35cm EPIX LAPA GRASPER, 10/BX CB030, 5mmx35cm EPIX LAPA SCISSOR, 10/BX CFF73, 12x100 Kii Fios ADVFIX 6/BX CFF03, 5x100 Kii Fios ADVFIX 6/BX CFF33, 11X100 Kii Fios ADVFIX 6/BX CY010, 5mmX35cm EPIX LAPA DISSECT, 10/BX C2201, 120MM INSUFF NEEDLE XE, 20/BX CA090, DIRECT DRIVE LCA 3/BX C8702, M ALEXIS LAP SYS W/Kii Fios 5/BX
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KKX | Drape, Surgical | General, Plastic Surgery | 878.4370 | 2 |
| GEI | Electrosurgical, Cutting & Coagulation & Accessories | General, Plastic Surgery | 878.4400 | 2 |
| HET | Laparoscope, Gynecologic (And Accessories) | Obstetrics/Gynecology | 884.1720 | 2 |
| NWV | Laparoscopic Accessories, Gynecologic | Obstetrics/Gynecology | 884.1720 | 1 |
| FHF | System, Evacuator, Fluid | Gastroenterology, Urology | 876.4370 | 2 |
| GCJ | Laparoscope, General & Plastic Surgery | Gastroenterology, Urology | 876.1500 | 2 |
| FZP | Clip, Implantable | General, Plastic Surgery | 878.4300 | 2 |
| MDM | Instrument, Manual, Surgical, General Use | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33961 | General surgical procedure kit, non-medicated, single-use | A typically non-dedicated collection of various surgical instruments, sometimes with dressings and/or other materials, but that does not contain pharmaceuticals, intended to be used during: 1) open abdominal surgery; 2) a range of open surgical procedures across multiple clinical specialties (non-dedicated); 3) non-orthopaedic trauma surgery; 4) minor dermatological surgery; or 5) cosmetic surgery below the head. As a kit that includes procedural devices, it is neither dedicated to surgical scrubbing, surgical patient preparation, nor anaesthesia, and is not a dedicated biopsy kit. This is a single-use device. | No | Active |
| 12750 | Spring-loaded pneumoperitoneum needle, single-use | A slender, sharply-pointed metal tube designed to introduce or remove gas from the peritoneal cavity as a therapeutic or surgical/radiological procedural method. It is often inserted into the peritoneal cavity for the purpose of insufflation [e.g., with carbon dioxide (CO2)] to establish pneumoperitoneum prior to abdominal endoscopy. It is equipped with a spring-loaded, round-tipped obturator that extends from the tube when the device does not encounter resistance (i.e., when the cavity has been reached) to prevent damage from the sharp point. This is a single-use device. | No | Active |
| 58045 | Laparoscopic electrosurgical blunt dissector | A sterile, rigid, laparoscopic device, covered with a sheath of electrical insulation, designed to perform through a compatible laparoscopic instrument (e.g., an access port) and to be connected to an electrosurgical diathermy generator when required to provide electrical current, to facilitate blunt dissection (e.g., hernia repair, cholecystectomy, colectomy) between tissue planes accessible via the abdominal cavity. It is a monopolar device typically constructed as a long insulated metal instrument whose distal end is equipped with a stainless steel scissors-like tip of various configurations operated through scissors-like ring handles at the proximal end. This is a single-use device. | No | Obsolete |
| 42412 | Laparoscopic access cannula, single-use | A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments; it may additionally be intended for thoracoscopy whereby the valve may not be required. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. This is a single-use device. | No | Active |
| 58039 | Endoscopic electrosurgical handpiece/electrode, monopolar, single-use | A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece and may include a lumen for suction/irrigation; it requires a patient contact return electrode to complete the circuit. It is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and may be designed to also mechanically cut tissues. This is a single-use device. | No | Active |
| 57956 | Rigid endoscopic grasping forceps, single-use | A sterile, rigid manual device used in combination with a compatible endoscope to grasp tissue (typically atraumatically) or foreign bodies. It is typically constructed as a very long instrument with one sliding and one stationary rod whose distal ends are equipped with grasping tongs or claws which are operated by scissors-like ring handles at the proximal end of the instrument. It is typically made of metal and plastic materials and is introduced into the body through the working channel of the endoscope to grasp internal structures for observation, excision, and/or biopsy procedures. This is a single-use device. | No | Obsolete |
| 47342 | Laparoscopic irrigation/aspiration cannula | A rigid, sterile, hand-operated, tube-like device intended to be inserted through a laparoscopic port to provide a conduit for the instillation and/or aspiration of fluid during laparoscopy. It has a single-lumen, a proximal handle, and is typically made of plastic materials. It is connected via tubing to an appropriate irrigating/aspirating device(s), the irrigation/aspiration being regulated by the operator with mechanical valve controls typically in the handle of the cannula. This is a single-use device. | No | Obsolete |
| 35649 | Ligation clip, metallic | A metallic, non-bioabsorbable clasp designed to be implanted around a blood vessel, lymphatic vessel, other tubular anatomy or a tissue bundle, for permanent occlusion. It may be used for ligation in open and endoscopic (e.g., laparoscopic) surgeries; a dedicated, disposable clip applier may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 20607915133898 | GS1 |
Customer Contacts
- Phone
- 1.949.713.8300
- [email protected]