FDA UDI
In Commercial Distribution
🇺🇸 United States
FRACTORA
DI: 17290016633181
·
Model: AG601260A
·
INMODE M.D LTD
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
5
Basic Information
- Brand Name
- FRACTORA
- Primary DI
- 17290016633181
- Version / Model
- AG601260A
- Catalog Number
- AG601260A
- Company Name
- INMODE M.D LTD
- Labeler DUNS
- 600417351
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2016-10-25
- Public Version
- 4
- Public Version Date
- 2023-11-03
- Public Version Status
- Update
- Public Device Record Key
- 0657cd0f-0b5b-4288-977e-b651626cac0a
Device Description
Fractora 60P
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Dry Heat Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | Electrosurgical, Cutting & Coagulation & Accessories | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58455 | Radio-frequency skin surface treatment system applicator | A handpiece component of a radio-frequency skin surface treatment system designed to be used by a healthcare professional to deliver bipolar radio-frequency (RF) energy to the skin surface for skin resurfacing. It is typically designed to deliver RF energy to the skin in a non-homogenous fractional manner, via an array of multi-electrode pins, to leave minimal-impact areas of skin to facilitate healing. The applicator connects with the system’s control unit and may include vacuum to facilitate its coupling with the skin. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 17290016633181 | GS1 | ||||
| Unit of Use | 07290016633184 | GS1 |
Customer Contacts
- Phone
- 1-887-367-4556
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K102461 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 35 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 90 Percent (%) Relative Humidity
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 50 – 110 KiloPascal
- Type
- Handling Environment Temperature
- Temperature Range
- 15 – 30 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 80 Percent (%) Relative Humidity
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 90 – 110 KiloPascal