FDA UDI
In Commercial Distribution
🇺🇸 United States
M-Drain
DI: 15711055001851
·
Model: DS2010600
·
Mermaid Medical A/S
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- M-Drain
- Primary DI
- 15711055001851
- Version / Model
- DS2010600
- Catalog Number
- DS2010600
- Company Name
- Mermaid Medical A/S
- Labeler DUNS
- 308951313
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 4
- Public Version Date
- 2022-10-10
- Public Version Status
- Update
- Public Device Record Key
- 215009ce-26d3-4be1-b8ff-74b8e95ba8b0
Device Description
The Percutaneous Introducer is used to dilate for placement of a .035” or .038” guide wire where the puncture is performed with a 21G needle (fine needle).
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DRE | Dilator, Vessel, For Percutaneous Catheterization | Cardiovascular | 870.1310 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60437 | Interventional radiology percutaneous-access kit, single-use | A collection of various instruments/devices (e.g., introducer sheath, dilator, guides, cannula, needle, angiographic catheter) intended to be used for percutaneous body-access to facilitate a radiological image-guided interventional radiology or surgical procedure [e.g., bile duct biopsy, percutaneous transhepatic cholangiogram, non-vascular drainage procedures, ultrasound-guided spinal surgery]. Some types are designed to function as a channel to facilitate the introduction of radiological image guidance devices (e.g., ultrasound probe/transducer) [not included]. It does not contain pharmaceuticals. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 05711055001854 | GS1 | Retail box | 5 | In Commercial Distribution | |
| Primary | 15711055001851 | GS1 |
Customer Contacts
- Phone
- +4547108570
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K071330 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Kit | ||
| Length | 20 | Centimeter | |
| Catheter Gauge | 6 | French |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight and keep dry
- Type
- Storage Environment Temperature
- Temperature Range
- -29 – 60 Degrees Celsius