FDA UDI
In Commercial Distribution
🇺🇸 United States
PERCUVANCE
DI: 14026704582805
·
Model: IPN027870
·
TELEFLEX INCORPORATED
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
1
Basic Information
- Brand Name
- PERCUVANCE
- Primary DI
- 14026704582805
- Version / Model
- IPN027870
- Catalog Number
- PCVHCA5
- Company Name
- TELEFLEX INCORPORATED
- Labeler DUNS
- 002348191
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-11-16
- Public Version
- 9
- Public Version Date
- 2021-01-25
- Public Version Status
- Update
- Public Device Record Key
- 5c26b234-3483-4b74-a824-4abf0b5046bf
Device Description
HEM-O-LOK CLIP APPLIER
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | Electrosurgical, cutting & coagulation & accessories | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35798 | Open-surgery ligation clip applier | A hand-held manual surgical instrument designed to apply small atraumatic clips (not included) for the ligation of blood vessels, or similar tubular anatomy, mainly to prevent and/or stop bleeding (i.e., haemostasis) during an open-surgery procedure. It may also be used to apply small clamps (e.g., bulldog type) to tissues however it is not intended to apply an aneurysm clip. The device is typically a metallic instrument with flat, curved ends to hold and deliver the clips (e.g., forceps-like); implantable clips are not included. This is a reusable device after sterilization. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 34026704582809 | GS1 | Box | 36 | In Commercial Distribution | |
| Package | 24026704582802 | GS1 | Box | 6 | In Commercial Distribution | |
| Primary | 14026704582805 | GS1 |
Customer Contacts
- Phone
- +1(919)544-8000
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K153063 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Width | 0.22 | Inch | |
| Length | 2.8 | Inch |
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- -29 – 60 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- 16 – 37 Degrees Celsius