FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Integra Expandable Interbody
DI: 10889981049355
·
Model: 82-3012
·
SEASPINE ORTHOPEDICS CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Integra Expandable Interbody
- Primary DI
- 10889981049355
- Version / Model
- 82-3012
- Catalog Number
- 82-3012
- Company Name
- SEASPINE ORTHOPEDICS CORPORATION
- Labeler DUNS
- 079840876
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-09-24
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- d53a2f6f-958f-4798-af28-8f2b5547188f
- Distribution End Date
- 2018-01-27
Device Description
IMPLANT, 30mm LG, 12-18mm HT, 10mm WD, 0 DEG. The Integra Expandable IBD System consists of lumbar interbody fusion devices manufactured from PEEK-OPTIMA® LT1 (ASYM F2026), titanium (Ti-6AI-4V ELI per ASTM F136) and cobalt chromium (Co-28Cr-6Mo per ASTM F1537) materials, with radiopaque tantalum markers (ASTM F560).
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MAX | Intervertebral fusion device with bone graft, lumbar | Orthopedic | 888.3080 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 57806 | Vertebral body prosthesis, non-sterile | A non-sterile implantable device designed to replace or repair (fuse) the spinal bony segments, or vertebrae, lost or injured as a consequence of, e.g., trauma, deformity, tumour, or degenerative disease. It is typically intended to be used with supplemental spinal fixation and may be used with a bone graft. It is usually made of metal, polymer, or a combination of these materials. This device must be sterilized prior to use. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10889981049355 | GS1 |
Customer Contacts
- Phone
- +1(866)942-8698
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K133418 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 30mm LG, 12-18mm HT, 10mm WD, 0° |