FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Ventlab
DI: 10889483172452
·
Model: 5714F-SE
·
VENTLAB, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Ventlab
- Primary DI
- 10889483172452
- Version / Model
- 5714F-SE
- Catalog Number
- 5714F-SE
- Company Name
- VENTLAB, LLC
- Labeler DUNS
- 038305402
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-08-01
- Public Version
- 3
- Public Version Date
- 2025-09-24
- Public Version Status
- Update
- Public Device Record Key
- 36fafd15-874b-4f59-bf42-0156f300682c
- Distribution End Date
- 2025-09-23
Device Description
Adult 14ft ETCO2 Oral Nasal Cannula Assembly with Fits-all & Reflective Connector
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CCK | ANALYZER, GAS, CARBON-DIOXIDE, GASEOUS-PHASE | Anesthesiology | 868.1400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 17614 | Exhaled-gas oesophageal intubation detector | A device designed to verify proper endotracheal (ET) tube placement by detecting/assessing exhaled carbon dioxide (CO2) during airway management to confirm correct intubation for appropriate ventilation; it may additionally be intended to confirm placement/ventilation when using a laryngeal mask airway and/or face mask. It is intended to be connected to the intubation device and/or ventilator breathing circuit (e.g., the T-piece connector or hose). It typically functions through colorimetric CO2 detection using a chemical reaction based and/or paper indicator that changes colour based on the approximate CO2 concentration. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10889483172452 | GS1 |
Customer Contacts
- Phone
- +1(800)433-2797
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 14 | Feet |