FDA UDI
In Commercial Distribution
🇺🇸 United States
Snowden-Pencer
DI: 10885403172519
·
Model: SP8464
·
CAREFUSION 2200, INC
Product Codes
1
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Snowden-Pencer
- Primary DI
- 10885403172519
- Version / Model
- SP8464
- Catalog Number
- SP8464
- Company Name
- CAREFUSION 2200, INC
- Labeler DUNS
- 832696038
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-10-17
- Public Version
- 7
- Public Version Date
- 2023-04-04
- Public Version Status
- Update
- Public Device Record Key
- 57d5d844-d783-40aa-8705-61721ed58552
Device Description
CROCODILE SA ERGONOMIC MODULAR 5MM,45CM,ESU INSERT
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, general & plastic surgery | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62061 | Endoscopic electrosurgical electrode, monopolar, reusable | An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece/housing and has no electrical or mechanical controls (e.g., does not include controlling ring-handles); it is not intended for gas-enhanced electrosurgery. This is a reusable device. | No | Active |
| 13730 | Device sterilization/disinfection container, reusable | A receptacle designed to hold wrapped and/or unwrapped medical/dental devices in a chemical washer/disinfector and/or sterilizer during the washing/disinfection and/or sterilization cycle(s). It may be designed as a tray to allow full or partial immersion of the devices in a liquid disinfectant, or as an enclosed box to prevent contamination once the sterilization process is finished. The container may also be used for transport and storage of the processed devices, and may have features such as an expiry date label, breathing filter, built-in slots or inserts to hold instruments, and stacking capabilities. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10885403172519 | GS1 |
Customer Contacts
- Phone
- +1(800)323-9088
- [email protected]
- Phone
- +1(800)323-9088
- [email protected]