FDA UDI
In Commercial Distribution
🇺🇸 United States
AirLife
DI: 10885403171031
·
Model: RC6Y006094
·
Carefusion Corporation
Product Codes
1
GMDN Terms
2
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- AirLife
- Primary DI
- 10885403171031
- Version / Model
- RC6Y006094
- Catalog Number
- RC6Y006094
- Company Name
- Carefusion Corporation
- Labeler DUNS
- 830432451
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-01
- Public Version
- 4
- Public Version Date
- 2022-10-24
- Public Version Status
- Update
- Public Device Record Key
- bc15a672-22d5-4b71-a311-8e0e98a3d00f
Device Description
Airlife™ Isothermal™ Breathing Circuit Adult Respiratory Circuit Non-heated, MR850
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BZE | HEATER, BREATHING SYSTEM W/WO CONTROLLER (NOT HUMIDIFIER OR NEBULIZER | Anesthesiology | 868.5270 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35113 | Non-heated respiratory humidifier | A device designed to prevent the drying of airway passages associated with the inhalation of oxygen (O2) by adding water vapour to the dry gas as it is passed through, or more seldom, over water. It typically consists of a graduated container (reservoir) for the water, a top piece that functions as a detachable lid (typically a screw lid with a gastight seal), and a tube that protrudes into the water to divert the gas below the water level. This device, commonly known as a bubble humidifier, does not heat the water. It has connectors: 1) one (e.g., a winged nut) that connects to an oxygen therapy flowmeter; and 2) one to which the patient tubing is connected. This is a reusable device. | No | Active |
| 37706 | Ventilator breathing circuit, single-use | An assembly of devices designed to conduct air or oxygen (O2) enriched gases and additional gases [e.g., nitrous oxide (N2O), halogenated gases] from a ventilator to a patient artificial airway/respiratory mask (not included). It includes breathing tubes, a Y-piece connector, and provides connections for devices that humidify, deliver medication, and monitor gas concentration or pressure within the breathing circuit; some types may include a carbon dioxide cuvette and/or an integrated heating wire powered by a connected humidifier intended to warm breathing gases as they enter the patient's airway. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 50885403171039 | GS1 | Case | 20 | In Commercial Distribution | |
| Primary | 10885403171031 | GS1 |
Customer Contacts
- Phone
- +1(800)323-9088
- [email protected]