FDA UDI
In Commercial Distribution
🇺🇸 United States
V. Mueller
DI: 10885403028076
·
Model: CH5625
·
CAREFUSION 2200, INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- V. Mueller
- Primary DI
- 10885403028076
- Version / Model
- CH5625
- Catalog Number
- CH5625
- Company Name
- CAREFUSION 2200, INC
- Labeler DUNS
- 832696038
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-08-09
- Public Version
- 2
- Public Version Date
- 2024-02-02
- Public Version Status
- Update
- Public Device Record Key
- 56df71ed-8431-476b-ae59-9ebfda00c95b
Device Description
V. Mueller MERZ AORTA PUNCH STRAIGHT PUNCH SIZE 5MM OVERALL LENGTH 8-1/2" (21.6CM)
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DWS | INSTRUMENTS, SURGICAL, CARDIOVASCULAR | Cardiovascular | 870.4500 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35285 | Aorta punch, reusable | A manual surgical instrument designed to cut a circular plug of tissue from the wall of the aorta to create an anastomosis site during vascular surgery. It consists of a pointed, cone-shaped, disk-like tip on the end of a plunger that is inserted through a small incision made; its diameter corresponds to the size of the hole. Behind the tip is a thinner section which entraps (holds) the tissue as the sharp circular blade is pressed down the plunger by the surgeon into and through the tissue. It is typically made of high-grade stainless steel and is available in various punch sizes. It can equally be used to punch holes in other vessels if needed. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10885403028076 | GS1 |
Customer Contacts
- Phone
- +1(800)323-9088
- [email protected]