FDA UDI
In Commercial Distribution
🇺🇸 United States
Valleylab FX8
DI: 10884521780415
·
Model: VLFX8GENZE
·
Covidien LP
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Valleylab FX8
- Primary DI
- 10884521780415
- Version / Model
- VLFX8GENZE
- Company Name
- Covidien LP
- Labeler DUNS
- 058614483
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-09-09
- Public Version
- 3
- Public Version Date
- 2023-04-04
- Public Version Status
- Update
- Public Device Record Key
- b1d19fe3-d05b-483f-89d2-2a474de6667b
Device Description
FX Series Energy Platform
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | Electrosurgical, cutting & coagulation & accessories | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 11490 | Electrosurgical system generator | An electrically-powered component of a electrosurgical system intended to generate radio-frequency (RF) electrical current for subsequent cutting and coagulation of soft tissues during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system generator). It includes controls, may include an integrated surgical plume (smoke) suction unit, and is intended to be connected via a cable to an electrosurgical handpiece and electrode (neither of these are included); it is not intended for inert gas-enhanced electrosurgery. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10884521780415 | GS1 |
Customer Contacts
- Phone
- +1(508)261-8000
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K181389 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- The system can be stored for up to 1 year without performance degradation upon use.
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 700 – 1060 millibar
- Type
- Handling Environment Humidity
- Temperature Range
- 15 – 85 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- 50 – 104 Degrees Fahrenheit
- Type
- Storage Environment Humidity
- Temperature Range
- 15 – 90 Percent (%) Relative Humidity
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 500 – 1060 millibar
- Type
- Storage Environment Temperature
- Temperature Range
- 14 – 140 Degrees Fahrenheit