FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 10884521134324
·
Model: 186-0150-PH
·
Covidien LP
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
5
Basic Information
- Brand Name
- NA
- Primary DI
- 10884521134324
- Version / Model
- 186-0150-PH
- Catalog Number
- 186-0150-PH
- Company Name
- Covidien LP
- Labeler DUNS
- 058614483
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2016-10-13
- Public Version
- 6
- Public Version Date
- 2021-11-10
- Public Version Status
- Update
- Public Device Record Key
- 6a5ddc97-131e-4182-bf5d-772bba2fad13
Device Description
Sensor Quatro Start-Up Kit
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GXY | ELECTRODE, CUTANEOUS | Neurology | 882.1320 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33586 | General-purpose multi-parameter bedside monitor | An electrically-powered device/device assembly designed for the continuous assessment of several vital physiologic parameters (e.g., ECG, blood pressure, heart rate, temperature, cardiac output, apnoea, and respiratory/anaesthetic gas concentrations) of one patient in intensive or general healthcare settings. It typically set-up by the patient bedside and often includes programmable alarms, portable radio transmitters, receivers, and antennas (telemetry systems) to allow monitoring during patient ambulation or transportation; it is not dedicated to neonatal use and is not intended to be worn on the body. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10884521134324 | GS1 | ||||
| Unit of Use | 20884521134321 | GS1 |
Customer Contacts
- Phone
- +1(508)261-8000
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K093183 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Fragile; Keep dry; This side up;
- Type
- Storage Environment Temperature
- Temperature Range
- -10 – 50 Degrees Celsius