FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Versaport Plus
DI: 10884521076228
·
Model: NB11STS
·
Covidien LP
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Versaport Plus
- Primary DI
- 10884521076228
- Version / Model
- NB11STS
- Company Name
- Covidien LP
- Labeler DUNS
- 058614483
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 10
- Public Version Date
- 2023-07-27
- Public Version Status
- Update
- Public Device Record Key
- 3f074df7-8361-4eae-baee-6d17afe9686d
- Distribution End Date
- 2022-04-22
Device Description
Bladeless Trocar
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, general & plastic surgery | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38456 | Laparoscopic multi-instrument access port, single-use | A sterile sleeve assembly made of plastic materials intended to retract a small abdominal incision to allow multiple laparoscopic instruments to pass into the abdomen at the same time during a laparoscopic procedure. It will typically have an introducer that creates the abdominal incision (but is not used in cases where the surgeon chooses to make the incision), and a valve component that maintains the pneumoperitoneum established for the surgical procedure. It allows for the introduction of multiple instruments and/or a camera port, and removal of larger specimens during minimally-invasive laparoscopic surgery. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 20884521076225 | GS1 | CASE | 6 | Not in Commercial Distribution | 2022-04-22 |
| Primary | 10884521076228 | GS1 |
Customer Contacts
- Phone
- +1(508)261-8000
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K081169 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 11 | Millimeter | |
| Outer Diameter | 5 | Millimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 59 – 86 Degrees Fahrenheit
- Type
- Handling Environment Temperature
- Temperature Range
- – 130 Degrees Fahrenheit