FDA UDI
In Commercial Distribution
🇺🇸 United States
microTargeting™ STar™ Insertion Tube Set
DI: 10873263007683
·
Model: FC9003-00768
·
FHC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
5
Basic Information
- Brand Name
- microTargeting™ STar™ Insertion Tube Set
- Primary DI
- 10873263007683
- Version / Model
- FC9003-00768
- Catalog Number
- FC9003
- Company Name
- FHC, INC.
- Labeler DUNS
- 108179458
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2019-12-27
- Public Version
- 1
- Public Version Date
- 2020-01-06
- Public Version Status
- New
- Public Device Record Key
- ecfadf5c-393e-47a9-9fa1-04ea23409192
Device Description
microTargeting STar Drive Single Electrode Insertion Tube Set, 5x, Sterile, for use with Nexframe and STar Drive. Contains: IT(DB7): Insertion Tube with Stylet - 205.6mm length, 1.83mm OD, 1.6mm ID PT(DB7) Protective Tube - 1.50mm OD, 0.58mm ID
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Ethylene Oxide", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HAW | Neurological stereotaxic Instrument | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62753 | Intracerebral cannula, nonimplantable, single-use | A sterile, nonimplantable, rigid tube intended to be surgically inserted through the skull to access the brain (e.g., cerebral ventricles) for cerebrospinal fluid (CSF) drainage, infusion of materials, and/or for use as a port through which instruments, leads and/or probes can be passed to perform a variety of diagnostic, treatment, or surgical procedures. It is usually made of metal (e.g., stainless steel) and may include a stylet/trocar blade. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10873263007683 | GS1 | ||||
| Unit of Use | 00873263007686 | GS1 |
Customer Contacts
- Phone
- +1(800)326-2905
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K092562 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity