FDA UDI
Not in Commercial Distribution
🇺🇸 United States
microTargeting™ Electrode and Insertion Tube Kit
DI: 10873263001346
·
Model: KTF1002-00134
·
FHC, INC.
Product Codes
3
GMDN Terms
2
Identifiers
2
Pkg Device Count
5
Basic Information
- Brand Name
- microTargeting™ Electrode and Insertion Tube Kit
- Primary DI
- 10873263001346
- Version / Model
- KTF1002-00134
- Catalog Number
- KTF1002
- Company Name
- FHC, INC.
- Labeler DUNS
- 108179458
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2016-08-22
- Public Version
- 5
- Public Version Date
- 2023-01-10
- Public Version Status
- Update
- Public Device Record Key
- 1225e8bc-d50a-4dcb-b9ed-c08e99312aa9
- Distribution End Date
- 2023-01-10
Device Description
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Ethylene Oxide", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HAO | INSTRUMENT, SURGICAL, NON-POWERED | Neurology | 882.4535 | 1 |
| GZL | ELECTRODE, DEPTH | Neurology | 882.1330 | 2 |
| HAW | Neurological stereotaxic Instrument | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61964 | Intracerebral cannula, implantable | A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade. | Yes | Active |
| 32556 | Depth electrode | An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10873263001346 | GS1 | ||||
| Unit of Use | 00873263001349 | GS1 |
Customer Contacts
- Phone
- +1(800)326-2905
- [email protected]
Storage Conditions
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity