FDA UDI
Not in Commercial Distribution
🇺🇸 United States
microTargeting™ Electrode and Insertion Tube Kit
DI: 10873263001322
·
Model: FC7100-00132
·
FHC, INC.
Product Codes
2
GMDN Terms
2
Identifiers
2
Pkg Device Count
5
Basic Information
- Brand Name
- microTargeting™ Electrode and Insertion Tube Kit
- Primary DI
- 10873263001322
- Version / Model
- FC7100-00132
- Catalog Number
- FC7100
- Company Name
- FHC, INC.
- Labeler DUNS
- 108179458
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2016-08-22
- Public Version
- 6
- Public Version Date
- 2023-01-10
- Public Version Status
- Update
- Public Device Record Key
- a172ff84-6530-4663-9b94-c35d3a52319f
- Distribution End Date
- 2023-01-10
Device Description
Array Insertion Electrode/Tube with Stylet Kit, 5x, Sterile, for use with Nexframe and microTargeting Drive. Contains: IT(AR8): Insertion Tube w/ Stylet. MTDPBN(PA)(DB2): microTargeting Electrode. Individual Specifications: IT(AR8) - 217mm tube length, 0.89mm OD, 0.58mm ID MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm differential length, 234.2mm protective tube length. 1 Meg RZAP, 0.56mm od
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Ethylene Oxide", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GZL | ELECTRODE, DEPTH | Neurology | 882.1330 | 2 |
| HAW | Neurological stereotaxic Instrument | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61964 | Intracerebral cannula, implantable | A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade. | Yes | Active |
| 32556 | Depth electrode | An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10873263001322 | GS1 | ||||
| Unit of Use | 00873263001325 | GS1 |
Customer Contacts
- Phone
- +1(800)326-2905
- [email protected]
Premarket Submissions
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius