FDA UDI
Not in Commercial Distribution
🇺🇸 United States
microTargeting™ Electrodes
DI: 10873263001292
·
Model: FC2004-00129
·
FHC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
5
Basic Information
- Brand Name
- microTargeting™ Electrodes
- Primary DI
- 10873263001292
- Version / Model
- FC2004-00129
- Catalog Number
- FC2004
- Company Name
- FHC, INC.
- Labeler DUNS
- 108179458
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 5
- Record Status
- Published
- Publish Date
- 2016-08-22
- Public Version
- 6
- Public Version Date
- 2023-01-10
- Public Version Status
- Update
- Public Device Record Key
- 1489c656-856d-4132-b6f4-7cfa317c93a5
- Distribution End Date
- 2023-01-10
Device Description
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Moist Heat or Steam Sterilization", "Ethylene Oxide"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GZL | ELECTRODE, DEPTH | Neurology | 882.1330 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32556 | Depth electrode | An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10873263001292 | GS1 | ||||
| Unit of Use | 00873263001295 | GS1 |
Customer Contacts
- Phone
- +1(800)326-2905
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K033173 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 227.2 | Millimeter | |
| Length | 242.2 | Millimeter | |
| Device Size Text, specify | Impedance: Megaohms | ||
| Outer Diameter | 0.56 | Millimeter | |
| Length | 10 | Millimeter |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity