Basic Information
- Brand Name
- xCupTM
- Primary DI
- 10867802000273
- Version / Model
- DUE-1117X-071-01
- Catalog Number
- DUE-1117X-071-01
- Company Name
- ESCREEN, INC.
- Labeler DUNS
- 014079359
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 25
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 4
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- ae833c52-e3d1-45c7-b1a0-f3f273111a6a
Device Description
The xCupTM for use with the xReaderTM is for in vitro diagnostic use and is intended for prescription use in laboratories, point-of-care and workplaces by trained users. The test is not intended for over-the-counter use. The test device cannot be read visually and must be used with the xReaderTM. The xCupTM qualitatively detects drug classes in human urine at the following cut-off concentrations: Amphetamines at 500 ng/ml; Barbiturates at 300 ng/mL; Benzodiazepines at 300 ng/mL; Cocaine at 150 ng/mL; Methamphetamines at 500 ng/mL; Methadone at 300 ng/mL; Morphine at 300 ng/mL and 2000 ng/mL; Oxycodone at 100 ng/mL; Phencyclidine at 25 ng/mL; and Marijuana at 50 ng/mL. Configurations of the xCupTM may consist of any combination of the listed drug analytes. The xCupTM only provides a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography / mass spectrometry (GC/MS), high performance liquid chromatography (HPLC) or liquid chromatography / tandem mass spectrometry (LC/MS/MS) are the preferred confirmatory methods. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are obtained.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXM | Enzyme Immunoassay, Benzodiazepine | Clinical Toxicology | 862.3170 | 2 |
| DIS | Enzyme Immunoassay, Barbiturate | Clinical Toxicology | 862.3150 | 2 |
| DIO | Enzyme Immunoassay, Cocaine And Cocaine Metabolites | Clinical Toxicology | 862.3250 | 2 |
| LDJ | Enzyme Immunoassay, Cannabinoids | Clinical Toxicology | 862.3870 | 2 |
| LCM | Enzyme Immunoassay, Phencyclidine | Unknown | U | |
| DNK | Thin Layer Chromatography, Morphine | Clinical Toxicology | 862.3640 | 2 |
| DJR | Enzyme Immunoassay, Methadone | Clinical Toxicology | 862.3620 | 2 |
| DJG | Enzyme Immunoassay, Opiates | Clinical Toxicology | 862.3650 | 2 |
| DJC | Thin Layer Chromatography, Methamphetamine | Clinical Toxicology | 862.3610 | 2 |
| DKZ | Enzyme Immunoassay, Amphetamine | Clinical Toxicology | 862.3100 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46994 | Multiple drugs of abuse IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of multiple drugs of abuse in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10867802000273 | GS1 | ||||
| Unit of Use | 00867802000276 | GS1 |
Customer Contacts
- Phone
- 800-881-0722