FDA UDI
In Commercial Distribution
🇺🇸 United States
Tempo Temporary Pacing Lead, Curved
DI: 10866899000210
·
Model: TC1106
·
BIO TRACE MEDICAL
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Tempo Temporary Pacing Lead, Curved
- Primary DI
- 10866899000210
- Version / Model
- TC1106
- Catalog Number
- TC1106
- Company Name
- BIO TRACE MEDICAL
- Labeler DUNS
- 044674446
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-06-15
- Public Version
- 1
- Public Version Date
- 2018-07-16
- Public Version Status
- New
- Public Device Record Key
- 7d1df49f-4154-4428-90be-f4591e05bdeb
Device Description
The BioTrace Medical Tempo Temporary Pacing Lead is designed for temporary intracardia pacing. The lead provides access to the right ventricle via either the femoral vein, subclavian vein or the internal jugular vein approach and may be shaped near the distal end to facilitate delivery. It is a radiopaque, polymeric lead featuring a balloon , active fixations, bipolar electrodes and a soft tip.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- Yes
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LDF | Electrode, Pacemaker, Temporary | Cardiovascular | 870.3680 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35854 | Temporary cardiac pacing balloon catheter | A sterile, flexible, balloon-tipped, tube designed to deliver temporary pacing stimuli to the heart; it may detect bioelectric signals from the heart. It is used in the atria and/or ventricles and has electrodes which are usually applied to the ventricles and connect to an external pacemaker that generates the electrical pacing impulses. It may be unipolar or bipolar and facilitate the display of electrocardiographic signals. It is used: 1) in an emergency during bradycardia or asystole until a pacemaker can be implanted to control the heart rate; 2) during and/or after surgery; or 3) during cardiac catheterization [e.g., electrophysiological (EP) examinations]. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10866899000210 | GS1 |
Customer Contacts
- Phone
- 650-799-4999
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K160260 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 110 | Centimeter | |
| Catheter Gauge | 6 | French |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 32 – 131 Degrees Fahrenheit