FDA UDI
In Commercial Distribution
🇺🇸 United States
uSp02
DI: 10843997007679
·
Model: 9477
·
MASIMO CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- uSp02
- Primary DI
- 10843997007679
- Version / Model
- 9477
- Company Name
- MASIMO CORPORATION
- Labeler DUNS
- 780421038
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-10-08
- Public Version
- 1
- Public Version Date
- 2021-10-18
- Public Version Status
- New
- Public Device Record Key
- 56b2830d-9079-4059-99a4-260f81bf875f
Device Description
uSpO2 Pulse Oximetry Cable for GE ApexPro FH, with LNCS Sansor Sample Pack
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQA | Oximeter | Cardiovascular | 870.2700 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36554 | Patient monitoring system module, pulse oximetry | A small unit dedicated to the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in blood using light detection methods (spectrophotometry) after light is emitted from a light-emitting diode (LED) situated in the connected probe. It is designed to operate as part of a patient monitoring system enhancing the function of this system (the parent device). The module automatically plugs into the parent device when the user places it into a standardized slot in the parent device or a connected module rack. The parent device operates as a mainframe computer displaying the pulse oximetry parameters provided by this module. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10843997007679 | GS1 |
Customer Contacts
- Phone
- +1(949)297-7498
- [email protected]
Storage Conditions
- Type
- Handling Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- -40 – 70 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -40 – 70 Degrees Celsius