FDA UDI
In Commercial Distribution
🇺🇸 United States
Clarus Digital Inspection Scope, 1.9mm OD
DI: 10810004820002
·
Model: CD2-1100
·
CLARUS MEDICAL, LLC
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Clarus Digital Inspection Scope, 1.9mm OD
- Primary DI
- 10810004820002
- Version / Model
- CD2-1100
- Catalog Number
- CD2-1100
- Company Name
- CLARUS MEDICAL, LLC
- Labeler DUNS
- 010316284
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-07-21
- Public Version
- 1
- Public Version Date
- 2022-07-29
- Public Version Status
- New
- Public Device Record Key
- 31f3489f-baee-4d33-a1ce-3786592b4dee
Device Description
The Clarus Inspection Scope is a device with a flexible working length intended for the visual examination of the lumen of an instrument (typically an endoscope) to identify any dirt/debris within the lumen so that it can be removed prior to disinfection/sterilization; it is not intended for patient examination. The device includes an image sensor chip to convey images. This is a reusable device.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- Yes
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MNL | Accessories, Cleaning Brushes, For Endoscope | Gastroenterology, Urology | 876.1500 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62721 | Instrument inspection scope | An endoscope-like device with a flexible working length intended for the visual examination of the lumen of an instrument (typically an endoscope) to identify any dirt/debris within the lumen so that it can be removed prior to disinfection/sterilization; it is not intended for patient examination. The device includes a fibreoptic bundle or charge-coupled device (CCD) to convey images. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Direct Marking | 00810004820005 | GS1 | ||||
| Primary | 10810004820002 | GS1 |
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- -20 – 60 Degrees Celsius