FDA UDI
In Commercial Distribution
🇺🇸 United States
Detector Drug Cup
DI: 10722355002573
·
Model: HCDOAV-3104
·
IMMUNOSTICS COMPANY, INC
Product Codes
9
GMDN Terms
1
Identifiers
3
Pkg Device Count
25
Basic Information
- Brand Name
- Detector Drug Cup
- Primary DI
- 10722355002573
- Version / Model
- HCDOAV-3104
- Company Name
- IMMUNOSTICS COMPANY, INC
- Labeler DUNS
- 119214195
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 25
- Record Status
- Published
- Publish Date
- 2018-05-21
- Public Version
- 3
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- 965b215a-c629-4842-9506-3c67989e831e
Device Description
A rapid, one step screening test for the simultaneous, qualitative detection of multiple drugs and drug metabolites in human urine.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DJR | Enzyme immunoassay, methadone | Clinical Toxicology | 862.3620 | 2 |
| DIO | Enzyme immunoassay, cocaine and cocaine metabolites | Clinical Toxicology | 862.3250 | 2 |
| LAF | Gas chromatography, methamphetamine | Clinical Toxicology | 862.3610 | 2 |
| JXM | Enzyme immunoassay, benzodiazepine | Clinical Toxicology | 862.3170 | 2 |
| LDJ | Enzyme immunoassay, cannabinoids | Clinical Toxicology | 862.3870 | 2 |
| DKZ | Enzyme immunoassay, amphetamine | Clinical Toxicology | 862.3100 | 2 |
| DJG | Enzyme immunoassay, opiates | Clinical Toxicology | 862.3650 | 2 |
| DIS | Enzyme immunoassay, barbiturate | Clinical Toxicology | 862.3150 | 2 |
| LCM | Enzyme immunoassay, phencyclidine | Unknown | U |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46994 | Multiple drugs of abuse IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of multiple drugs of abuse in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 20722355002570 | GS1 | Case of 4 | 4 | In Commercial Distribution | |
| Primary | 10722355002573 | GS1 | ||||
| Unit of Use | 80722355002572 | GS1 |
Customer Contacts
- Phone
- +1(732)918-0770
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 2 – 30 Degrees Celsius
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep test cup in the package until ready for use. DO NOT FREEZE.