FDA UDI
In Commercial Distribution
🇺🇸 United States
Halyard
DI: 10680651406085
·
Model: 40608
·
Avanos Medical, Inc.
Product Codes
1
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Halyard
- Primary DI
- 10680651406085
- Version / Model
- 40608
- Catalog Number
- MCK2-17-75-4
- Company Name
- Avanos Medical, Inc.
- Labeler DUNS
- 079375431
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-30
- Public Version
- 5
- Public Version Date
- 2021-12-13
- Public Version Status
- Update
- Public Device Record Key
- 6c0b2721-14e6-467c-80ab-fcbd67f6791f
Device Description
HALYARD* Multi-COOLED RF Kit
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GXI | PROBE, RADIOFREQUENCY LESION | Neurology | 882.4725 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44063 | Neurosurgical procedure kit, non-medicated, single-use | A collection of various sterile neurosurgical instruments, dressings and the necessary materials used to perform a neurosurgical procedure. It does not contain pharmaceuticals. This is a single-use device. | No | Active |
| 57972 | Radio-frequency ablation system | An assembly of devices designed to generate and apply radio-frequency (RF) electrical current for heating via an electrode(s) in a precise location, at a controlled temperature, for focal ablation of non-cardiac tissues, including nerves, tumours, precancerous tissue; it may be intended for coagulation however it is not intended for electrosurgical cutting. It typically includes a mains electricity (AC-powered) RF current generator, controls, cables, and an appropriate electrosurgical ablation probe, catheter, and/or handpiece with electrode(s). | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10680651406085 | GS1 |
Customer Contacts
- Phone
- +1(844)425-9273
- [email protected]