FDA UDI
In Commercial Distribution
🇺🇸 United States
PlumeSafe® X5™
DI: 10653405987994
·
Model: PX5-135-22
·
Conmed Corporation
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- PlumeSafe® X5™
- Primary DI
- 10653405987994
- Version / Model
- PX5-135-22
- Catalog Number
- PX5-135-22
- Company Name
- Conmed Corporation
- Labeler DUNS
- 071595540
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-08-12
- Public Version
- 2
- Public Version Date
- 2026-04-17
- Public Version Status
- Update
- Public Device Record Key
- 6330d7ad-9fa1-4ff2-8f6c-fd48cca0dbf3
Device Description
Filter, 7/8” (22 mm), 3/8” (9.5 mm), 7/8” (22 mm) Ports
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FYD | APPARATUS, EXHAUST, SURGICAL | General, Plastic Surgery | 878.5070 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44979 | Surgical plume evacuation system filter | A screening device designed for use with a surgical smoke evacuation system, to entrap particulates from the plume of smoke created typically through the use of various tissue-burning surgical devices (e.g., laser, electrosurgical diathermy device), to prevent this from exhausting into the ambient air or evacuation tubing/pipeline systems. It will typically have a hydrophobic membrane that retains the particulate/bacterial pathogens through a combination of mechanical, electrostatic, or other means. The device comes in various sizes and designs. This is a reusable device, typically with a limited lifetime (e.g., 5 hours, 20 procedures, or weekly exchange). | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10653405987994 | GS1 |
Customer Contacts
- Phone
- +1(866)426-6633
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K240127 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -34 – 65 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 85 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -29.2 – 149 Degrees Fahrenheit