FDA UDI
In Commercial Distribution
🇺🇸 United States
FORE-SIGHT®
DI: 10609538710046
·
Model: 01-07-1004
·
CAS MEDICAL SYSTEMS, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- FORE-SIGHT®
- Primary DI
- 10609538710046
- Version / Model
- 01-07-1004
- Company Name
- CAS MEDICAL SYSTEMS, INC.
- Labeler DUNS
- 122211543
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-03-06
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- 3f2d9168-4d3a-4a02-8740-ae07043fa23a
Device Description
Tissue Oximeter Sensor (Single Medium)
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MUD | Oximeter, Tissue Saturation | Cardiovascular | 870.2700 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46618 | Tissue saturation oximeter sensor, single-use | A photoelectric device that is applied externally to a site on the body surface of a paediatric or adult patient for transcutaneous measurement the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivered to that tissue, typically during circulatory or perfusion examinations of skeletal muscle or when there is a suspicion of compromised circulation. It is connected to a tissue saturation oximeter via a fibreoptic cable and will typically include a light shield to protect the measurements from ambient light. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10609538710046 | GS1 | ||||
| Package | 30609538710040 | GS1 | 10 | In Commercial Distribution |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K112820 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 4.0 | Centimeter |