FDA UDI
In Commercial Distribution
🇺🇸 United States
Bovie
DI: 10607151009929
·
Model: E15604
·
BOVIE MEDICAL CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
10
Basic Information
- Brand Name
- Bovie
- Primary DI
- 10607151009929
- Version / Model
- E15604
- Catalog Number
- E15604
- Company Name
- BOVIE MEDICAL CORPORATION
- Labeler DUNS
- 079940465
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 10
- Record Status
- Published
- Publish Date
- 2020-11-16
- Public Version
- 2
- Public Version Date
- 2023-04-04
- Public Version Status
- Update
- Public Device Record Key
- 307ea8ae-86a2-4a0d-9db5-39863ad0a243
Device Description
Loop, 15 x 12mm, 4.0” length
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HGI | Electrocautery, Gynecologic (And Accessories) | Obstetrics/Gynecology | 884.4120 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44776 | Electrosurgical system | An assembly of devices intended to generate, and apply radio-frequency (RF) alternating current to soft tissues for cutting and coagulation during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system). The assembly includes a mains electricity-powered (AC-powered) RF generator with monitoring functions/controls, connection cables, a handpiece, and electrodes to apply the energy to the surgical site. Tissue resistance to the electrical current creates the heat as the current travels through the body between electrodes; it is not intended for inert gas-enhanced electrosurgery. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | 00607151009922 | GS1 | ||||
| Primary | 10607151009929 | GS1 |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 75 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 30 Degrees Celsius