FDA UDI
Not in Commercial Distribution
🇺🇸 United States
TruArch® Subtalar Implant System
DI: 10381780247524
·
Model: TA-3110
·
Ascension Orthopedics, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- TruArch® Subtalar Implant System
- Primary DI
- 10381780247524
- Version / Model
- TA-3110
- Catalog Number
- TA-3110
- Company Name
- Ascension Orthopedics, Inc.
- Labeler DUNS
- 942377524
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-09-05
- Public Version
- 5
- Public Version Date
- 2023-05-02
- Public Version Status
- Update
- Public Device Record Key
- 5348232d-fdf0-4c3a-a606-b08f6a7f0e75
- Distribution End Date
- 2023-03-31
Device Description
Integra® TruArch® The TruArch driver is used for insertion of the implant, as well as adjusting position.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HXX | SCREWDRIVER | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33968 | Surgical screwdriver, reusable | A non-powered tool intended to fit into a screw head (e.g., slotted, cross/hex head) for the application of rotation to introduce/remove a screw (e.g., craniofacial bone screw, dental screw) into/from a patient in association with a surgical procedure [e.g., orthopaedic, dental, computer assisted surgery (CAS), image registration]. It may also be used to connect/disconnect a device to/from another device attached to a patient (e.g., implant component, fiducial marker). The proximal end of the device may have a handle for manual use or a profiled tang that fits into an independent chuck or power driver; it is typically made of metallic and/or polymer materials. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Secondary | M269TA31101 | HIBCC | ||||
| Primary | 10381780247524 | GS1 |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 165.1 mm L x 4 mm dia tip |