FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Construct ™
DI: 10381780244226
·
Model: CSK-5010-01
·
Ascension Orthopedics, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Construct ™
- Primary DI
- 10381780244226
- Version / Model
- CSK-5010-01
- Catalog Number
- CSK501001
- Company Name
- Ascension Orthopedics, Inc.
- Labeler DUNS
- 942377524
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-08-30
- Public Version
- 5
- Public Version Date
- 2023-05-03
- Public Version Status
- Update
- Public Device Record Key
- 23e9b901-5f82-4d17-859b-dc796d53ade4
- Distribution End Date
- 2023-03-31
Device Description
Construct® Ankle Fusion Plate System The Construct Ankle Fusion Plating System Countersink with AO QC is used to add space or clearance for the head of a screw being placed in the bone.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LXH | ORTHOPEDIC MANUAL SURGICAL INSTRUMENT | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33968 | Surgical screwdriver, reusable | A non-powered tool intended to fit into a screw head (e.g., slotted, cross/hex head) for the application of rotation to introduce/remove a screw (e.g., craniofacial bone screw, dental screw) into/from a patient in association with a surgical procedure [e.g., orthopaedic, dental, computer assisted surgery (CAS), image registration]. It may also be used to connect/disconnect a device to/from another device attached to a patient (e.g., implant component, fiducial marker). The proximal end of the device may have a handle for manual use or a profiled tang that fits into an independent chuck or power driver; it is typically made of metallic and/or polymer materials. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Secondary | M269CSK5010011 | HIBCC | ||||
| Primary | 10381780244226 | GS1 |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 4.75 in L |