FDA UDI
In Commercial Distribution
🇺🇸 United States
CAPTURE™
DI: 10381780241829
·
Model: AI-1040
·
Ascension Orthopedics, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- CAPTURE™
- Primary DI
- 10381780241829
- Version / Model
- AI-1040
- Catalog Number
- AI-1040
- Company Name
- Ascension Orthopedics, Inc.
- Labeler DUNS
- 942377524
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-09-05
- Public Version
- 6
- Public Version Date
- 2023-02-22
- Public Version Status
- Update
- Public Device Record Key
- 9b6a02e7-71ad-498f-a034-5a18e68ee163
- Distribution End Date
- 2026-12-31
Device Description
CAPTURE™ Cannulated Screw System The screw removal instrument is used in conjunction with the Capture Cannulated Screw System.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LXH | ORTHOPEDIC MANUAL SURGICAL INSTRUMENT | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 64479 | Surgical implant handling forceps | A hand-held manual surgical instrument with blades designed to grasp and manipulate a surgical implant (excluding sutures) during implantation; it is not intended for use on tissues, is not a dental or ophthalmic device, and is not a dedicated tissue clip applier. It is made of metal materials and may have one of various designs (e.g., tweezers-, scissors-, alligator-like) whereby the blades are designed to be opened/closed to handle a variety of implantable devices (e.g., orthopaedic joint prosthesis, breast implant, surgical mesh). This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Secondary | M269AI10401 | HIBCC | ||||
| Primary | 10381780241829 | GS1 |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 5.4 in L |