FDA UDI
In Commercial Distribution
🇺🇸 United States
CUSA® Clarity
DI: 10381780126263
·
Model: C7036
·
INTEGRA LIFESCIENCES (IRELAND) LIMITED
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- CUSA® Clarity
- Primary DI
- 10381780126263
- Version / Model
- C7036
- Catalog Number
- C7036
- Company Name
- INTEGRA LIFESCIENCES (IRELAND) LIMITED
- Labeler DUNS
- 989925396
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-11-23
- Public Version
- 10
- Public Version Date
- 2023-04-14
- Public Version Status
- Update
- Public Device Record Key
- 33455232-ac61-4b8e-937c-c7b9b9903fa2
Device Description
CUSA® Clarity Handpiece, Cleaning Brush
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LFL | Instrument, ultrasonic surgical | Unknown | U | |
| LBK | Device, neurosurgical fragmentation and aspiration | Unknown | U |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44750 | Soft-tissue ultrasonic surgical system handpiece, reusable | A hand-held component of an ultrasonic surgical system intended to convert high frequency electrical current from a generator into an ultrasonic oscillation for a tip placed at its end to mechanically fragment soft-tissue cells upon contact for cutting and/or coagulating tissue during surgery. The handpiece may also serve as a conduit for irrigation and aspiration during surgery. It is typically in the form of a pen/pencil or elongated probe with permanently attached cables. This is a non-dedicated device intended to be used in multiple clinical specialties. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10381780126263 | GS1 |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep Dry
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 500 – 1060 millibar
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 85 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- 10 – 35 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- -18 – 60 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 15 – 85 Percent (%) Relative Humidity