FDA UDI
In Commercial Distribution
🇺🇸 United States
Titan™ Reverse Shoulder System
DI: 10381780121688
·
Model: GBP096003015
·
Ascension Orthopedics, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Titan™ Reverse Shoulder System
- Primary DI
- 10381780121688
- Version / Model
- GBP096003015
- Catalog Number
- GBP-0960-030-15
- Company Name
- Ascension Orthopedics, Inc.
- Labeler DUNS
- 942377524
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-10-09
- Public Version
- 5
- Public Version Date
- 2023-01-25
- Public Version Status
- Update
- Public Device Record Key
- 47c5d2ed-cde8-4590-a52a-adccdb02b035
- Distribution End Date
- 2026-12-31
Device Description
The Titan Reverse Shoulder baseplate is a glenoid component secured by four peripheral screws, two of which can be locked, as well as a central larger compression screw. The baseplate is partially coated with asymmetrical sintered beads for secondary fixation.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KWS | PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED | Orthopedic | 888.3660 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 48091 | Reverse shoulder prosthesis base plate | A sterile component of a reverse shoulder prosthesis that consists of a metal plate [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] intended to be firmly attached to the scapula with screws. It is intended to serve as the foundation for the reverse shoulder prosthesis head (glenosphere). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10381780121688 | GS1 | ||||
| Secondary | M268GBP0960030151 | HIBCC |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K130050 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 15 mm |