FDA UDI
In Commercial Distribution
🇺🇸 United States
Integra®
DI: 10381780072362
·
Model: NL8502001
·
Integra Lifesciences Corporation
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
1
Basic Information
- Brand Name
- Integra®
- Primary DI
- 10381780072362
- Version / Model
- NL8502001
- Catalog Number
- NL8502001
- Company Name
- Integra Lifesciences Corporation
- Labeler DUNS
- 083171244
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-09-22
- Public Version
- 7
- Public Version Date
- 2024-02-05
- Public Version Status
- Update
- Public Device Record Key
- 50311759-f8ce-4599-bd47-f8eada0441a2
Device Description
Integra® Disposable Peritoneal Catheter Passer
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GYK | Instrument, shunt system implantation | Neurology | 882.4545 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46801 | Subcutaneous tunneller, single-use | A hand-held manual surgical instrument designed to create a subcutaneous tunnel (artificial passageway) between percutaneous entry and exit incisions for the subcutaneous placement of a device (e.g., catheter for medication administration, shunt). It is available in a variety of forms and may be: 1) a luminal sheath with a removable inner obturator, intended for co-axial device introduction, followed by sheath removal; or 2) a non-luminal device intended to either lead or pull the device through subcutaneous tissue. It is not intended for tunnelling through deep tissues and is not a dedicated pacing or defibrillation lead tunneller. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 30381780072366 | GS1 | BOX | 6 | In Commercial Distribution | |
| Primary | 10381780072362 | GS1 | ||||
| Secondary | M269NL85020011 | HIBCC |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K895868 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Obturator length: 60.0 cm |