FDA UDI
In Commercial Distribution
🇺🇸 United States
QWIX®
DI: 10381780052876
·
Model: 119138ND
·
NEWDEAL
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- QWIX®
- Primary DI
- 10381780052876
- Version / Model
- 119138ND
- Company Name
- NEWDEAL
- Labeler DUNS
- 536935331
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-05-26
- Public Version
- 5
- Public Version Date
- 2023-02-09
- Public Version Status
- Update
- Public Device Record Key
- 201adc52-e503-4ef7-8403-2f4718008716
- Distribution End Date
- 2027-12-31
Device Description
The quick coupling straight handle is used to connect the screwdriver axes with 6.0mm diameter tri shank attachments for motor or hand power to implant or explant 4.3mm screws.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LXH | ORTHOPEDIC MANUAL SURGICAL INSTRUMENT | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47829 | Surgical instrument handle, non-torque-limiting | A hand-held manual surgical instrument designed to attach to the proximal end of a surgical instrument (e.g., a screwdriver shaft) to allow the surgeon to perform manipulations with the instrument, such as manual rotation of a bone screw or reamer; it does not include a torque-limiting function. The device is typically made of metal and/or synthetic material and may have a straight or T-shaped handle grip which may include additional features such as a ratchet mechanism to allow the surgeon to maintain a constant hold on the handle when providing rotation in one direction. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Secondary | M248119138ND1 | HIBCC | ||||
| Primary | 10381780052876 | GS1 |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]