FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Licox®
DI: 10381780041207
·
Model: IT2
·
GMS, Gesellschaft für medizinische Sondentechnik mbH
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Licox®
- Primary DI
- 10381780041207
- Version / Model
- IT2
- Catalog Number
- IT2
- Company Name
- GMS, Gesellschaft für medizinische Sondentechnik mbH
- Labeler DUNS
- 315902197
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-01
- Public Version
- 5
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- 0e39c245-473c-49c0-81b6-9c9219000a1a
- Distribution End Date
- 2016-08-04
Device Description
Licox® Complete Brain Tunnelling Probe Kit
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GWM | DEVICE, MONITORING, INTRACRANIAL PRESSURE | Neurology | 882.1620 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61398 | Intracerebral sensor catheter, short-term | A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (ICP), temperature, partial pressure of oxygen (pO2)]; it may in addition be intended for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemotherapeutic agents, radioisotopes). It may include accessory devices intended to facilitate catheter introduction, stabilization, and/or fluid collection/infusion (e.g., stylet, bolts, drills, drainage/infusion port/reservoir). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Secondary | M273IT21 | HIBCC | ||||
| Primary | 10381780041207 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K053244 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 130 mm x 35 mm x 313 mm |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep Away From Sunlight
- Type
- Handling Environment Temperature
- Temperature Range
- 2 – 10 Degrees Celsius