FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Contour-Flex Valve and Shunt System
DI: 10381780036784
·
Model: CFRH
·
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Contour-Flex Valve and Shunt System
- Primary DI
- 10381780036784
- Version / Model
- CFRH
- Catalog Number
- CFRH
- Company Name
- INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
- Labeler DUNS
- 531408342
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-01
- Public Version
- 5
- Public Version Date
- 2021-04-07
- Public Version Status
- Update
- Public Device Record Key
- aa10af67-b0ff-4cbb-bbfe-9ce5f7974168
- Distribution End Date
- 2021-01-31
Device Description
The Integra Contour-Flex Valve is a multi-function membrane valve with occluders and integral connectors. It is used in treatment of patients with hydrocephalus when shunting cerebrospinal fluid (CSF) from ventricles of the brain. The Contour-Flex Valve design includes a flat silicone membrane, which provides resistance to CSF flow. The Contour-Flex Valve is available in two sizes: Regular and Small. Both sizes are available in 3 pressure/flow characteristics ranges: low, medium, and high.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- MR Safe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXG | Shunt, central nervous system and components | Neurology | 882.5550 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61123 | Ventriculo-peritoneal/atrial shunt | An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the brain ventricles to either the peritoneal cavity or the heart right atrium (i.e., dual-capability), where it can be absorbed into the body, as a treatment for increased intracranial pressure (e.g., caused by hydrocephalus). It consists of: 1) an intracerebral ventricular catheter through which CSF flows; 2) a mechanical shunt valve that typically opens at a pre-set pressure; and 3) a peritoneal/atrial catheter that channels the CSF to the peritoneal cavity or right atrium; some types have a port/reservoir for hypodermic sampling/infusion. Disposable devices associated with implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10381780036784 | GS1 | ||||
| Secondary | M272CFRH1 | HIBCC |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | High Pressure at 20ml/h: 12.7-18.0cmH2O |