FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Ventricular Catheter
DI: 10381780035879
·
Model: 9MZ205
·
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Ventricular Catheter
- Primary DI
- 10381780035879
- Version / Model
- 9MZ205
- Catalog Number
- 9MZ205
- Company Name
- INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
- Labeler DUNS
- 531408342
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-01
- Public Version
- 4
- Public Version Date
- 2023-02-09
- Public Version Status
- Update
- Public Device Record Key
- a668fd18-05da-446a-9aaf-54675dc00ffd
- Distribution End Date
- 2021-12-31
Device Description
Ventricular Catheters are provided Straight, Finned or Right Angle (inner diameter 1.4mm, outer diameter 2.7mm). They are delivered with an Introducer. Marked Ventricular Catheters feature radiopaque Length Markings at 2.0 cm Intervals from the Tip. A Straight or Right Angle Connector, and/or a silicone Right Angle Guide, are supplied as Accessories.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- MR Safe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXG | Shunt, central nervous system and components | Neurology | 882.5550 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61376 | Intracerebral infusion/drainage catheter, long-term | A sterile, flexible tube intended to be surgically inserted through the skull for long-term (> 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemotherapeutic agents); it is typically used for measurement of intracranial pressure (ICP) and as part of a shunt system. It may include an attached port/reservoir at its proximal end that is placed subcutaneously to facilitate material infusion/collection, and/or accessory devices intended to facilitate catheter introduction and/or stabilization (e.g., stylet, catheter holder); it does not include a sensor. This is a single-use device. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10381780035879 | GS1 | ||||
| Secondary | M2729MZ2051 | HIBCC |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K911433 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 5cm Proximal Length x 2cm Distal Length x 2.7mm O.D. x 1.4mm I.D. (F8) |